HomeMy WebLinkAbout#3 Site Plan - Intek
To: Planning Commissioners
From: Justin Fortney, City Planner
Date: October 10, 2022
Item: Site Plan – Intek Addition – 2022-52– 1000 Spiral Blvd.
Planning Commission Action Requested
Review the proposed site plan and make a recommendation to the City Council.
Background Information
The applicants are proposing to add a 60,200 Square-foot addition onto the existing building,
parking lot addition, and related site improvements for drainage and landscaping. The addition will
be primarily for warehousing. Additional manufacturing lines will be added in place of the relocated
warehousing.
Comprehensive Plan
The property is guided Industrial within the 2040 Comprehensive Plan.
Zoning
The property is zoned I-1 – Industrial Park. Allowable uses include manufacturing, warehousing
and similar.
Existing Condition
The existing site was constructed in 1985 and has about 127,000 square-feet of manufacturing,
warehousing, and related office space.
Adjacent Zoning and Land Use
The following land uses abut the property:
Direction Use Comp Plan District Zoning District
North Veteran’s Park Park PI – Public Institutional
East Cranky Ape Auctions Industrial I-1 – Industrial Park
South Processing Industrial I-1 – Industrial Park
West Misc. Industrial Industrial I-1 – Industrial Park
Planning Commission Memorandum
Site Plan Review
Vehicular Access and Circulation
The existing site works well. There are three entrances on two streets. Changes proposed include
a parking lot addition to the east lot and improvements to the truck access loop for the new
loading docks. A future driveway is planned through the east lot to Enterprise Avenue.
Building Setbacks
There are no prescribed minimum setbacks within the zoning district, however, proposed setbacks
are reviewed during site plan review for conformity with the area. Proposed setbacks are within
existing building setbacks, except to the rear. The rear setback is proposed at 28-feet, which is 10-
feet further than the much smaller adjacent building to the west. Veteran’s Park is to the north.
There is dense vegetation on the south side of Veteran’s Park for screening, along what is
proposed on site.
Required Parking
Parking minimums are met. The existing and proposed building sizes require 187 parking spaces
based on manufacturing and warehousing uses. A total of 190 spaces are proposed after the
additional 28 are constructed.
* Warehouse and Manufacturing: 1 per 1,000 SF (minimum one per employee)
Architectural Design
The applicant is proposing construction with a similarly textured precast panel as the existing
building. These panels fit the class II building material description. The western façade is visible
from the public street necessitating at least 65% class II materials and 25% Class I (glass, brick,
natural stone). The applicants are proposing nearly 100% class II with the textured precast panels
on the western side and zero class I. The city has been supportive of an increase of type II for a
reduction of type I, when a façade is less visible and particularly when it is an existing building
addition. This western side is the most visible as it is facing Millard Avenue, but is about 260-feet
away with trees in-between.
The only type III material proposed is on the south elevation. It is a small area between the two
conjoined structures where the new structure extends about six-feet higher than the existing
building.
Landscape Plan
The proposed landscaping was significantly influenced by the City’s Tree Replacement Guidelines.
About 100 trees are proposed for removal in order to construct the addition and grading for the
drainage plan. Most of the significant trees that must be replaced are Boxelder, Cottonwood, and
Tatarian Maples. They are mostly in a few clumps on the north and east parts of the site. They will
be replaced with 111 3-inch caliper trees around the site, which will improve the street scape and
site screening. The City Forester is reviewing the proposed species.
Lighting Plan
Lighting locations will be similar to existing with automatic LED wall pack lighting on the building
and some LED pole lights in the parking lot to match existing.
Grading, Drainage, Erosion Control and Utility Plan Review
The drainage, grading and erosion control plan is being reviewed by the City Engineering
Department for compliance. The proposed site drainage will mostly be directed to a proposed pond
on the eastern lot for treating and infiltration. Some existing drainage from Veteran’s Park will be
directed to a treatment and infiltration pond south of the water tower.
Recommendation
Approval of the Site Plan is recommended subject to the following conditions:
1. Conformance with the plans submitted with the Planning Commission Staff Report dated
October 10, 2022
2. All disturbed areas on the property shall be protected to eliminate erosion control
problems.
3. Approval of a building permit.
4. Approval is subject to a one-year Sunset Clause; if significant progress is not made towards
the proposal within one year of City Council approval, the approval is null and void.
5. The City Engineering Department must approve the grading, drainage, and erosion control
plan and related conditions.
6. The City Forester must approve the proposed tree planting species of the landscaping plan.
ATTACHMENTS
• Site Location Map
• Site Pictures
• Architectural Elevations
• Site Plan Documents
Vet’s Park
East Lot
Enterprise Ave Water Tower
215.0
28.45'27.98'
244.88'
245.13'
CO
N
C
P
A
D
12" RCP CULVERTS
S0
0
°
0
1
'
1
9
"
W
7
4
1
.
5
PROPOSEDADDITION60,200 SF
2
8
0
.
0
0
2
8
0
.
0
0
215.00
65.74
9
3
.
5
1
62.80
56.96
A37.34
R40.00
A23.30
R15.00
NORTH
EXISTING 125,643 S.FBUILDING
PROPOSED BITUMINOUS PAVEMENT - SEE SECTION ON SHEET 15.
KEYNOTES:
PROPOSED CONCRETE- SEE SIDEWALK SECTION ON SHEET 15.
PROPOSED CONCRETE RETAINING WALL - SEE ARCHITECTURAL PLANS.
PROPOSED HEAVY DUTY CONCRETE - SEE SECTION ON SHEET 15.
PROPOSED SURFACES
EXISTING IMPERVIOUS SURFACES...........5.06 ACRES (220,644 S.F.)
PROPOSED IMPERVIOUS SURFACES.......1.75 ACRES(76,499 S.F.)
TOTAL IMPERVIOUS SURFACES............... 6.82 ACRES (297,143 S.F.)
TOTAL GREEN SPACE.................................6.60 ACRES (287,388 S.F.)
TOTAL LOT AREA.........................................13.42 (584,531 S.F.)
GREEN SPACE = 50% OF LOT
28.45'
133.87'
S0
0
°
0
1
'
1
9
"
W
7
5
8
.
0
N0
0
°
0
1
'
1
9
"
E
2
3
9
.
7
S89°58'41"E 565.0
12 16
POSSIBLE FUTURE DRIVEWAY
3.50'
3.45'
18.00'18.00'24.00'
2
8
0
.
0
0
R3.00A4.71
R3.00A4.71
20.00 6.
0
0
6
.
0
0
20.00
13
.
7
2
17.00
14
2
.
9
4
10
8
.
0
0
134.12'
PO
S
S
I
B
L
E
F
U
T
U
R
E
BUI
L
D
I
N
G
A
D
D
I
T
I
O
N
14.00
PROPOSED BITUMINOUS PAVEMENT - SEE SECTION ON SHEET 14.
KEYNOTES:
PROPOSED B618 CURB AND GUTTER - SEE DETAIL ON SHEET 14.
PROPOSED CONCRETE- SEE SIDEWALK SECTION ON SHEET 14.
NORTH
F&I 4 C.Y CLASS IV RIP RAPPROPOSED CURB CUT - SEE SECTION ON SHEET 14.
BOTANICAL NAME COMMON NAMEKEYQTY SIZE
PROPOSED TREE SCHEDULE
4
10
3"Robinia pseudoacaciaRP
3"Gleditisia triacanthosGT
39 3"Acer negundoAN
30 3"Populus section AigeirosPA
1 3"Acer saccharinumAS
3 3"Prunus serotinaPS
13 3"Acer tataricumAT
4 3"Ulmus pumilaUP
PROPOSED TREE REMOVAL SCHEDULE
BLACK LOCUST
HONEY LOCUST
BOX ELDER
COTTONWOOD
TATARIAN MAPLE
SIBERIAN ELM
SILVER MAPLE
BLACK CHERRY
CHINESE ELM
BLACK MULBERRY
WHITE ASHGREEN ASH
3"
3"
3"
3"
1 Ulmus parvifoliaCE
1 Morus nigraMN
1 Fraxinus americanaFA
4 Fraxinus pennsylvanicaFP
12" RCP CULVERTS
NORTH
1130
1129
1052
1144
1149
1150
1139 1140
PA
1052
11431442
2
1104
1107
1106
11051GT
1RP
111111091108
4AN
1138
1CE
1148
1333
1132 1131
1135
11371136
1147
1146
11127
1125
1124
1108
1120
1121
1117
1123
1122
1113
1112
1110
1114
1126
1134
1119
1118
3PS
1128
4UP
MN
11451116111511411099
1100
1102
1101
3PA
10961095
1097
10921091109010891088
1079
1086
1094
1093
3PA1RP
1076
1AS
1073
3AN1FA
1071
1087
1078
1083
1084
1085
4FP
1081
1075
1082
1080
4AN
1072
4AN
1RP
1074
1GT
1AT
1
RP
1
1GT
1AT
AT
GT 6PA
1 1077
3PA
1098
1103
CONC CURB AND GUTTER
CONC CURB AND GUTTER
CHAIN LINK FENCE
NORTH
122712121207
4
1GT
1AT
1AT
PA
1AT
1GT
3AN
2AN
3AN 1GT
AT
1
1220
1221
12221223 1225
1224
1AT
1226
1
1
27PA
1174 11
7
7
1AT
11
7
2
11
7
3
11
7
5
11
7
6
11
7
8
11
7
9
18
0 AT
5AN
1197
11641161
1162
1163
1165 1167 1168
1166
1GT
11
6
9
11
7
0
11
7
1
1205
1204
1202
1203
1216
12061208
1209
1210
1213 1214
1211
1215
1AT
1198
4AN
1198
1201
10AN
PA
AT
2
1154
1155
1146
1145
1144
114314421140
11531052
1052
1150
1156
1158
1AT
1
1159PARP
11181117
111511111109
1108
1110
1114
1104
1121
1116
110711081106
1105
1138
1149AN
1GT
1 4
1139
1141
1148
1131
1135 1147
1123 1125
1126
11241122
1134
1333
1132
1113 1120 113711361119
1098
1100
1112
1160
GT
1186
11871188
1189
1191
1190
1185
1229
1228
11831182
1184
1181
1193
1194
1217
1195
1196
1219
1192
1157
3PS
1MN
1CE
4UP
1127
1128
1127
1130
1129