HomeMy WebLinkAbout3 - CUP Hubs landing Marina
To: Planning Commission
From: Justin Fortney, City Planner
Date: June 27, 2022
Item: Conditional Use Permit 2022-45 – Marina – 6 Spiral View Loop
Planning Commission Action Requested:
The Planning Commission is asked to hold a public hearing and review the CUP (Conditional
Use Permit (essentially the same as a SUP) request for a marina in a Floodway District (Chapter
151.04)
Background Information:
On August 8, 2008, the City Council adopted a resolution recording a negative declaration on
the need for an Environmental Impact Statement for Hubs Landing. The conclusion was
based on the findings of an Environmental Assessment Worksheet (EAW), which was
completed at the request of the Minnesota Department of Natural Resources.
The City Council approved the CUP on January 5, 2009 and reauthorizing on November 1,
2010 authorizing the marina with the addition of 30 new slips. Between then and now,
about 2/3 of the slips were installed. The applicant is proposing to locate the last 11 slips
closer to the shore to the south. This modification to the operation requires a new CUP. The
original location of the final 11 slips was to be located on the south end of the long double
sided dock, but that section takes a great deal of strain due to river conditions.
Comprehensive Plan Classification
The 2040 Comprehensive Plan designates the property as Commercial
Zoning Classification
The subject property is zoned Floodway. The proposed use is allowed with a CUP, as outlined
below.
151.03A.1.Floodway District. The Floodway District shall include those areas designated as
floodway on the Flood Insurance Rate Maps.
151.04
C. Conditional Uses.
Planning Commission Memorandum
3. Marinas, boat rentals, docks, piers, wharves, and water control structures.
D. Standards For Floodway Conditional Uses.
1. All uses. No structure (temporary or permanent), fill (including fill for roads and levees),
deposit, obstruction, storage of materials or equipment, or other uses may be allowed as a
conditional use that will cause any increase in the stage of the 100-year or regional flood or
cause an increase in flood damages in the reach or reaches affected.
2. All floodway conditional uses shall be subject to the procedures and standards contained in
§151.10(D) of this Ordinance.
3.The conditional use shall be permissible in the underlying zoning district if one exists.
(floodway is currently considered “the” zoning district of the official zoning map)
4.Fill.
a. Fill, dredge spoil, and all other similar materials deposited or stored in the flood plain
shall be protected from erosion by vegetative cover, mulching, riprap or other acceptable
method.
b. Dredge spoil sites and sand and gravel operations shall not be allowed in the
floodway unless a long-term site development plan is submitted which includes an
erosion/sedimentation prevention element to the plan.
c. As an alternative, and consistent with Subsection (b) immediately above, dredge
spoil disposal and sand and gravel operations may allow temporary, on-site storage of fill or
other materials which would have caused an increase to the stage of the 100-year or regional
flood but only after the City has received an appropriate plan which assures the removal of
the materials from the floodway based upon the flood warning time available. The conditional
use permit must be title registered with the property in the Office of the County Recorder.
Review
The proposed use is being reviewed due to the configuration change of a previously approved
marina expansion CUP. The use is still allowable with possible conditions. The amount of
capacity (11 slips are proposed to complete the original plan) is limited to parking capacity and
assuring no adverse flooding impacts. Additionally, the DNR and Army Corps of Engineers will
assure the proposal will not interfere with navigability, flow, flood related impacts, necessary
dredging operations, etc.
All of these items were reviewed and approved for the original proposal. The modification of
the slip layout could have an impact on the original findings. The applicant’s engineer has
stated and provided some calculations showing that the proposed layout will have less of an
impact than previously proposed. His contention is that the location of the relocated dock will
have less of an impact on flood levels and flow in the river than previously approved because
it will be moved further from the flow line and protected by the existing upstream structures.
The DNR Floodplain (NFIP) Manager agrees that the proposed layout adequately supports that
the proposal won’t cause a rise in the flood elevations, as previously determined.
The Minnesota Department of Transportation reviewed the proposal and stated they have no
concerns since the project is outside their right-of-way and at least 40-feet from the bridge.
Adjacent Zoning and Land Use
The following land uses abut the property:
Direction Existing Use Zoning Comp Plan
North Captain’s Cove (marina) FW-Floodway Commercial
East Triplex FW-Floodway Commercial
South Mississippi River WAT- Water WAT- Water
West Mississippi River WAT- Water WAT- Water
Conditional Use Permit Review
The purpose of reviewing CUPs are to determine if any special conditions are necessary to
assure safe and consistent operation in the area.
Parking
The current parking areas are unimproved. There is not a specific number of spaces defined
for cars. The original CUP to add the 30 slips onto the existing 50 was approved without
requiring additional parking because they were discontinuing the fee based public launch.
They still have no launch available to the public, but do sell 12 launch passes per year and
have 25 possible marina members with trailered boats parked at the site for launching as
they wish. Not all of those storage/ launch memberships are sold.
There have been many cars parking on the street in front of the two marinas. This had
caused an issue with getting boat trailers in and out of the site, so the city installed some no
parking signs near the subject marina entrance at the request of the applicant. The applicant
states the vehicle parking on the street are not affiliated with the subject property.
Staff raised concerns about parking with the applicant who responded as follows:
- We have space available for car parking related to the future 11 slips and even more
if needed. If at any time we feel that parking is moving off site, besides reconfiguring,
we will limit the number of season passes and store and launch even more.
- There are 84 cars approximately (not counting space for store/ launch or season pass
parking) Does the city have a parking requirement for number of slips? Staff: No,
there is nothing specific to slips and some other situations that arise, but all vehicles
should be parked on site for normal business operations.
- We stack our parking at the marina so each party uses a single parking slot for the
cars they bring down that day. We have parking slots that stack up to 3 (a couple
even 4) vehicles. Not all our boaters are at the marina at one time; over the past 20
years we have had adequate parking on our property for our boaters and guests. In
the past, we had issues on Rivertown days when people not affiliated with the marina
use the street and our facilities to watch the fireworks, but now that the fireworks
are located near the railroad bridge, we do not have that problem.
Staff believes if all parking is occurring on site, 11 additional slips shouldn’t cause an issue if
the number of the two launching passes can be lowered, as may be needed.
Building improvements
None proposed
Notice
Notice was published and sent to property owners within 350-feet of the subject property.
No comments have been received at this time.
Recommendation
Staff recommends approval of the request as presented, subject to the following conditions:
1) City (and state when applicable) review and approval of any utility expansion or work.
2) The storage or processing of materials that are in time of flooding buoyant,
flammable, explosive, or could be injurious to human, animal, or plant life is
prohibited.
3) Storage of other material or equipment may be allowed if not subject to major
damage by floods and firmly anchored to prevent flotation or readily removable from
the area within the time available after flood warning.
4) Such fill, temporary dredging spoils, or other materials shall be protected against
erosion by rip-rap, vegetable cover, or bulk heading. Such fill or other materials to
receive and comply with all required city and DNR requirements and permits.
5) Approval is subject to a one-year Sunset Clause; if significant progress is not made
towards construction of the proposal within one year of City Council approval, the
approval is null and void.
6) Use of the property shall be limited to no more than 80 slips. No more than 12
launch passes and 25 marina storage and launch memberships shall be granted.
Public launching beyond shall be prohibited.
7) Parking that cannot be accommodated on site will require the reduction of existing
services until off street parking becomes adequate. parking expansion with approval
may also be allowed.
Attachments:
• Aerial Map
• Photographs
• Proposed plans
Dock
Location
Parking
Prior to stockpiling the dredge material in the dewatering area, silt fence or a gravel berm
will be installed between the dewatering area and the river to prevent sediment from
entering the river (see red line in Figure 1). Once the dredge material has dried sufficiently, it
will be loaded to trucks and hauled as stated above. Dredging is anticipated to be completed
yet this year if water level conditions allow.
Originally proposed
slip layout from
2009 application
approval
Current explanation of
change from applicant