Loading...
HomeMy WebLinkAbout4 - Enclave Apartments - 33rd St To: Planning Commission From: Justin Fortney, City Planner Date: February 14, 2022 Item: Public Hearing: Rezoning, Preliminary & Final Plat, and Site Plan – 2022-12 – Apartments – Vermillion St & 33rd St W Planning Commission Action Requested: The Planning Commission is asked to hold a public hearing, review the following proposals, and make a recommendation to the City Council. 1. Rezoning from C-4 to R-4 2. Preliminary and final plat 3. Site Plan for two apartment buildings and garages (211 units) Background Information: The subject property was guided and zoned commercial (C-4) for many years without any interest in commercial development. The area was studied during the last Comprehensive Plan update and changed to medium density residential (R-3/ R-4). Rezoning Review The property is guided for medium density residential, which allows for the density that is being proposed (211 units). Both R-3, Medium Density and R-4, high density would allow for the proposed density. Apartment buildings with singular entrances are permitted within the R-4 district, but only within R-3 districts when part of a PRD (planned residential development). The Cari Park Subdivision to the south is zoned R-3 - PRD, making the proposed R-4 district a good transition between existing residential and the commercial development. Aside from the subject property, there are 6.31 acres of vacant commercial property in this area for future development. There is also a similar amount of commercial redevelopment potential. Zoning Classification The subject property is zoned C-4, Regional Shopping Center, which allows commercial retail sales and services. Planning Commission Memorandum Adjacent Zoning and Land Uses Direction Existing Use Zoning Comp Plan North Me and Julio’s & H. County Inn/Ste C-4 Commercial East V State Bank/ Cross Rd Center C-4 Commercial South Cari Park Subdivision R3 - PRD Medium Density West T Hardware/ Dugarel’s C-4 Commercial Platting Review The Preliminary Plat will organize the parcels of land from different subdivisions and create a developable lot of record for the project. It’s reviewed to assure it meets all the ordinance requirements for land subdivision, along with technical requirements. The Final Plat approval would create the official plat to be recorded with the County Records, obligate the applicants to applicable development fees, and allow for the construction of approved plans. Fees Final Platting approval requires parkland dedication or cash in lieu of land to be used for area park improvements. This area has not been identified as a park location, so the $1,100 per unit cash rate for multi-family buildings would be applicable. There is an existing credit of $12,180 from the original County Crossroads Center Addition. Sewer interceptor fees are required at a rate of $485 for all residential units. Cash parkland dedication- 211 units X 1,100 = $232,100 - $12,180 = $219,920 Sewer interceptor 211 units X $485 = $102,335 Minnesota Department of Transportation Review Plans have been sent to the Minnesota Department of Transportation (MN DOT) as required for plats and site plans proposed that access state highways like 61. No comments have been received at this time. Site Plan Review Existing Condition The 15.66-acre site is currently vacant land. The southeast corner contains a drainage feature utilized by the commercial development to the east. Building Setbacks The proposed building setbacks are more than the required minimums of 20-feet front and rear. The sides are also more than the minimum of 23-feet (half of the building height). Vehicular Access and Circulation The site maintains the existing access areas and connects them through this site. There is a drive off the central entrance from 33rd Street that served little purpose other than access to the subject property if developed with multiple outlots. The drive connects to the back of the parking lot to the east. The parking lot still has access straight north to 33rd street and to this site by the southern connection. The Fire Marshal with the HFD has stated that they have adequate access to the proposed site. Some sidewalk connections are needed from the front of building two to the general site sidewalks. If building two has use of building one amenities, the main entrance or a secondary entrance should be considered on the north side of building two. This would significantly reduce the distance between the buildings. Parking and Loading Buildings with regular deliveries are required to have loading spaces. While there may not be regular deliveries for the building itself, there will surely be a lot of loading activity of people, packages, and mail. Due to the high number of units, delivery vehicles may be there for some time. Without a loading zone, the delivery vehicles will block parking spaces, garages, and drive isles. Loading zones near the main entrances would affect the proposed parking layout, but are necessary. The current parking standards are two spaces for each unit. With 211 units proposed, 422 parking spaces are required by ordinance. The site plan shows 391 total spaces on the site. Garage stalls make up 210 and the remaining 181 spaces are surface stalls. This is a rate of 1.85 spaces per unit. The applicant believes that is adequate for the project based on their experience. As an ordinance requirement, the minimum parking requirement must be satisfied. Available off-street parking within close proximity is allowed to satisfy the requirement. The entire Crossroads Center development is covered by an existing shared parking and access agreement. This provides the tenants and their visitors use of the existing parking in the center. This agreement satisfies the parking requirement. The center has far more parking available than is required or needed. Architectural Standards Architectural standards for multiple-family residential buildings require that front facades and other elevations that are highly visible from public streets and residential districts must be composed of at least 25% of Class 1 materials, and at least 25% of Class 2 materials. All elevations meet the minimum requirements of class 1 (glass and brick) and class 2 (fiber cement panels and siding or equivalent). There are no class 3 building materials proposed on the apartment buildings. The garages are proposed to have black asphalt shingles and white horizontal fiber cement siding or similar. Architectural standards material list Landscaping Based on the site size and amount of pavement, the zoning ordinance requires the following number of plantings: Type Required Proposed Tree 149 149 Shrubs 129 250 Staff believes the landscaping meets the ordinance requirements. At least one landscape island in needed on the south side of the north parking lot. Lighting A photometric plan must be submitted to assure light levels at the south property line are below .5 foot-candle adjacent to residential. The lighting plan must show that downfacing fixtures are utilized with auto switching controls. Notification Notice was published and sent to property owners within 350’ of the proposal. No specific comments have been received. Recommended Action: Approval of the rezoning, preliminary and final plat, and site plan, subject to the following conditions: 1) Conformance with the Planning Commission Staff Report and plans dated February 14, 2022. 2) All disturbed areas of the property shall be stabilized with rooting vegetative cover to eliminate erosion problems. 3) Any uncompleted site work must be escrowed at 125 percent of the estimated value prior to issuance of a certificate of occupancy. fiber cement panels/ siding Attachments: • Aerial photograph with general site layout • Photographs • Elevation drawings • Floor Plan, level one, building one • Site plans 4)The perimeter of the site must have erosion control, as approved by the City Engineering Department. 5)Approval is subject to a one-year Sunset Clause; if significant progress is not made towards construction of the proposal within one year of City Council approval, the site plan approval is null and void. 6)In addition to the landscaping shown on the plan, at least one landscape island is required on the south side of the north parking lot. 7)A right-of-way permit is required for any work in the public-rights-of-way. 8)Accommodate and or resolve any pending comments from the Minnesota Department of Transportation regarding their review of the project. 9)Provide waste enclosure designs/ elevations. 10)Submit a photometric plan. 11)The City Engineering Department must approve any required drainage plan, including: a.Stormwater Maintenance Agreement, which the City will draft for the infiltration basin. b.NPDES Permit - Required since project disturbs over 1 acre. c.The drainage area discharging to the infiltration basin should be expanded to include a portion of 33rd St (through the CBs) and possibly the parking lot of Hastings Country Inn. Adjust size of infiltration basin accordingly. 12)Water Service - Show any patchwork for the 33rd Street connection. City may require a gate valve where connection on to existing system. 13)Sanitary Service - Re-alignment of sanitary will require coordination with Crossroads Mall Inc. 14)Right after City Council approval of the final plat, submit the following prior to recording: a.Three owner signed mylar plats for city signatures b.Payment of $219,920 for cash in lieu of parkland dedication. c.Payment of $102,335 for sewer interceptor fees. 15)Connect the front of building two, to the site sidewalk system. 16)Include loading zones at the entrees of both buildings. 17)Submit a photometric plan .5 foot-candle adjacent to residential and auto switching controls. Looking East DUGAREL'S Terry’s Hardware Looking Southeast Looking Southwest Looking North from Tiffany Drive at path connection. Terry’s Hardware Vermillion State Bank Terry’s Hardware West Looking North from Tiffany Drive at path connection. Vacant Strip Mall Conceptual Rendering Elevation Drawings 2 3 41 C B A D A2 0 0 F4 A200H6 A2 0 0 A2 A200C4 A2 0 0 H1 3 A200C13 YO G A CL U B RO O M DOG WASH 37 ' - 4 " 12 ' - 0 " 22 ' - 0 " 36 ' - 0 " 24 ' - 0 " 19 ' - 0 " 24 ' - 0 " 36 ' - 0 " 22 ' - 0 " 12 ' - 0 " 1 0 ' - 8 " 4 ' - 3 " 6 ' - 2 " 4 ' - 3 " 1 0 ' - 1 0 " 18 ' - 8 " 10 ' - 1 0 " 4 ' - 3 " 6 ' - 2 " 4 ' - 3 " 2 2 ' - 8 " 6 8 ' - 0 " ELEV EQUIP. A3 0 1 3 A3 0 1 4 A3 0 0 A7 A3 0 0 A2 A3 0 0 A1 1 A3011 A3012 6 ' - 0 " 6'-0"68'-0" 37 ' - 4 " 36 ' - 0 " 24 ' - 0 " 24 ' - 0 " 24 ' - 0 " 24 ' - 0 " 36 ' - 0 " 24 ' - 0 " 10 ' - 8 " 1 4 ' - 8 " 21 ' - 4 " 14 ' - 8 " 1 0 ' - 8 " 22 ' - 0 " 36'-0"22'-0"31'-0"31'-0"24'-0"36'-0"24'-0"19'-0"24'-0"36'-0"32'-0"4'-1 5/8"31'-0"12'-0"24'-0"36'-0"36'-0"24'-0" A3 0 0 2 A3 0 0 3 A3 0 0 9 A3 0 1 6 5 5'-0"5'-0"JANITOR OF F I C E OF F I C E FI L E PA C K A G E RE C E P T I O N MA I L CO N F E R E N C E VE S T I B U L E LO B B Y FIT N E S S 2'-0" GO L F SI M U L A T O R KIT C H E N / B A R MA R K E T PO O L ME C H VESTMECHSHOWER MENSWOMENS F . P . GENERAL NOTESKEYNOTES:Signature:Date:License No. XXXXX 2021 YHR PARTNERS, LTD. L PROJECT NUMBER:Print Name:I hereby certify that this drawing, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 K J H G F E D C B A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15LKJHGFEDCBA-Telephone: (218)233-4422Moorhead, Minnesota 56560420 Main AvenueARCHITECTURE | PLANNING A120HASTINGS DEVELOPMENT HASTINGS, MINNESOTAENCLAVE Designer FIRST FLOOR PLAN -BUILDING 1 1/1 6 " = 1 ' - 0 " A1 2 0 A1 FI R S T F L O O R P L A N - B U I L D I N G 1 BLOCK 1 LOT 4 OUTLOT B 33RD STREET W VE R M I L L I O N S T R E E T (ST A T E T R U N K H I G H W A Y N O . 6 1 ) PATIO POOL PATIO PROPOSED BUILDING40,420 S.F. FFE=835.00 PROPOSED GARAGE FFE=833.10 PROPOSED GARAGEFFE=833.00 PROPOSED BUILDING40,700 S.F.FFE=834.50 PROPOSED GARAGE FFE=832.25 PROPOSED GARAGE FFE=832.25 PROPOSED GARAGE FFE=832.25 PROPOSED GARAGE FFE=832.25 PROPOSED GARAGE FFE=833.60 PROPOSED GARAGE FFE=834.35 PROPOSED GARAGE FFE=833.95 PROPOSED GARAGE FFE=835.00 DUM P S T E R DUM P S T E R DUM P S T E R DUMP S T E R INFILTRATION BASIN 4P BOTTOM = 824.00 100-YR HWL = 829.22 BASIN 3P NWL = 827.00 100-YR HWL = 831.44 M O N U M E N T MONUMENT 1 8 . 0 ' 2 4 . 0 ' 1 8 . 0 ' 1 5 . 0 ' 1 6 . 0 ' 7 . 0 ' 1 8 . 0 ' 2 4 . 0 ' 30.0' 5 . 0 ' 15.0' 24.0' 7.0'18.0'30.0' 1 8 . 0 ' 2 4 . 0 ' 3 0 . 0 ' 7.0' 24.0'30.0' 2 4 . 0 ' 3 0 . 0 ' 1 2 . 7 ' 22.0' 30.0'30.0'30.0'22.0'30.0' 9.0' 7 . 0 ' 1727 47 24 10 20 20 20 22 10 22 1832 26 16 826 26 2 4 . 0 ' 24.0' 7 . 0 ' B B F F F I J I J J I 3 0 . 0 ' 20' BUILDING SETBACK 20' BUILDING SETBACK 30.0'22.0' 1 2 . 7 ' 30.0' NO DATE BY CKD APPR SHEET OF Date License # Print Name: I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. DRAWN BY DESIGNED BY CHECKED BY PROJECT NO. PRELIMINARY DESIGN REVIEW PERMIT SUBMITTAL CONSTRUCTION DOCUMENTS REV. COMMENT Engineering | Surveying | Planning | Environmental 22 . 0 S ( L M S T E C H ) | RO H I T M A L I , E I T ( M N ) | 2/ 4 / 2 0 2 2 9 : 5 7 : 5 4 A M L: \ P R O J E C T S \ 5 0 5 1 3 \ C A D \ S H E E T S \ 5 0 5 1 3 - C 3 . 0 1 - S I T E P L A N . D W G :SI T E P L A N HASTINGS APARTMENTS PRELIMINARY PHASE ENCLAVE COMPANIES HASTING, MN TOT RM SCALE IN FEET 0 12060 NORTH L:\PROJECTS\50513\CAD\SHEETS\50513-C3.01-SITE PLAN.DWG: SITE PLAN22 . 0 S ( L M S T E C H ) | RO H I T M A L I , E I T ( M N ) | 2/ 4 / 2 0 2 2 9 : 5 7 : 5 4 A M L: \ P R O J E C T S \ 5 0 5 1 3 \ C A D \ S H E E T S \ 5 0 5 1 3 - C 3 . 0 1 - S I T E P L A N . D W G :SI T E P L A N C3.01SITE PLAN ---- THE SUBSURFACE UTILITY INFORMATION SHOWN ON THESE PLANS IS A UTILITY QUALITY LEVEL D. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF ASCE/CI 38-02, TITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA." THE CONTRACTOR AND/OR SUBCONTRACTORS SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, BY CONTACTING THE NOTIFICATION CENTER (GOPHER STATE ONE FOR MINNESOTA). THE CONTRACTOR AND/OR SUBCONTRACTOR AGREE TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH MIGHT BE OCCASIONED BY HIS OR HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES (UNDERGROUND AND OVERHEAD). IF THE CONTRACTOR ENCOUNTERS ANY DRAIN TILE WITHIN THE SITE, HE OR SHE SHALL NOTIFY THE ENGINEER WITH THE LOCATION, SIZE, INVERT AND IF THE TILE LINE IS ACTIVE. NO DRAIN TILE SHALL BE BACKFILLED WITHOUT APPROVAL FROM THE PROJECT ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. CONCRETE CURB EASEMENT LINE BUILDING LINE RETAINING WALL WET LAND TREE LINE SAW CUT LINE SIGN PROPOSED EXISTING LEGEND BOLLARD ##REGULAR PARKING STALL COUNT 1 KEYNOTE HEAVY DUTY ASPHALT PAVING CONCRETE PAVING CONCRETE SIDEWALK PAVEMENT BY OTHERS (SEE ARCHITECTURAL PLANS) BOUNDARY LINE AREA LOT 1 OUTLOT A TOTAL SITE AREA PARKING SUMMARY SURFACE STALLS GARAGE STALLS BUILDING SETBACKS FRONT YARD REAR YARD SIDE YARD -1/2 BUILDING HEIGHT PLUS 1/2 FT FOR EACH FOOT OVER 25 FT ZONING EXISTING ZONING PROPOSED ZONING DEVELOPMENT SUMMARY COMMERCIAL ACRES 4.86 10.81 15.67 181 210 20 FT 20 FT 00 FT C4 R4 STANDARD DUTY ASPHALT PAVING 33RD STREET W DUM P S T E R DUM P S T E R DUM P S T E R DUMP S T E R INFILTRATION BASIN 4P BOTTOM = 824.00 100-YR HWL = 829.22 BASIN 3P NWL = 827.00 100-YR HWL = 831.44 33RD STREET W 4 WP4 BF 4 WP 4 BS 3 TO TO 3 BS 3 BF 45 BSBF 44 BS4 BF 4 BS 4 BF 4 BS WP 6 3 TN 5 LH HA 6 GS 9 5 LHRSH 6 SG 2 RB 1 1 RB 2 RB IH 2 SG 1 BL 3 BL 1 2 BLBL 2 1 BL SG 3 IH 2 4 WS 2 BL2 BL 2 BL 2 BL 4 IH 1 BL 3 BL RP 3 SG 8 2 IH 1 IH 2 IH RP 3 8 LB 6 SBA 29 BIG 6 RSH IH 1 HA 4 HA 3 HA 6 3 LH HA 3 3 LH 6 HA 3 LH3 HA3 LH 3 LH 2 GS 3 LH4 HA 9 GS 3 LB GS 4 BIG 8 SBA 10 RSH 18 7 TN TN 3RSH 4 SBA 517 BIG 7 SBA 10 RSH2 LB7 SBA 6 LB 20 BIG RSH 14 5 LHRSH 8 RSH 8 LH 5 RP 3 RP 3 2 WS 2 WS WS 2 GS 6 6 GS 3 HA4 LB HA 3 4 LB HA 3 4 LB HA 3 LB 4 HA 3 LB 4 3 HALB 4 LB 4 HA 3 LB 4 HA 3 4 LB 3 HA LB 4 HA 3 4 LB 3 HA LB 4 HA 3 LB 4LB 4 3 HA3 HA 3 HA 4 LB 4 LB BF 4 LH 8 RSH 10 6 SBA SBA 6 7 TN 4 LH 5 RSH TN 18 4 SBA RP 3 RP 3 HA 7 7 HA 8 HA 6 HA NO DATE BY CKD APPR SHEET OF Date License # Print Name: DRAWN BY DESIGNED BY CHECKED BY I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly Licensed Landscape Architect under the laws of the State of Minnesota. PROJECT NO. PRELIMINARY DESIGN REVIEW PERMIT SUBMITTAL CONSTRUCTION DOCUMENTS REV. COMMENT Engineering | Surveying | Planning | Environmental 22 . 0 S ( L M S T E C H ) | RO H I T M A L I , E I T ( M N ) | 1/ 1 8 / 2 0 2 2 3 : 5 0 : 1 4 P M L: \ P R O J E C T S \ 5 0 5 1 3 \ C A D \ S H E E T S \ 5 0 5 1 3 - L 1 . 0 1 - L A N D S C A P E P L A N . D W G :L1 . 0 1 L A N D S C A P E P L A N HASTINGS APARTMENTS PRELIMINARY PHASE ENCLAVE COMPANIES HASTING, MN TOT RM SCALE IN FEET 0 12060 NORTH L:\PROJECTS\50513\CAD\SHEETS\50513-L1.01-LANDSCAPE PLAN.DWG: L1.01 LANDSCAPE PLAN22 . 0 S ( L M S T E C H ) | RO H I T M A L I , E I T ( M N ) | 1/ 1 8 / 2 0 2 2 3 : 5 0 : 1 4 P M L: \ P R O J E C T S \ 5 0 5 1 3 \ C A D \ S H E E T S \ 5 0 5 1 3 - L 1 . 0 1 - L A N D S C A P E P L A N . D W G :L1 . 0 1 L A N D S C A P E P L A N L1.01LANDSCAPE PLAN #### ---- THE SUBSURFACE UTILITY INFORMATION SHOWN ON THESE PLANS IS A UTILITY QUALITY LEVEL D. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF ASCE/CI 38-02, TITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA." THE CONTRACTOR AND/OR SUBCONTRACTORS SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, BY CONTACTING THE NOTIFICATION CENTER (GOPHER STATE ONE FOR MINNESOTA). THE CONTRACTOR AND/OR SUBCONTRACTOR AGREE TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH MIGHT BE OCCASIONED BY HIS OR HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UTILITIES (UNDERGROUND AND OVERHEAD). IF THE CONTRACTOR ENCOUNTERS ANY DRAIN TILE WITHIN THE SITE, HE OR SHE SHALL NOTIFY THE ENGINEER WITH THE LOCATION, SIZE, INVERT AND IF THE TILE LINE IS ACTIVE. NO DRAIN TILE SHALL BE BACKFILLED WITHOUT APPROVAL FROM THE PROJECT ENGINEER. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. CALCULATIONS ONE OVERSTORY TREE PER 4000 SQ FT OF PARKING LOT SIZE ONE OVERSTORY TREE PER 50 FT OF LOT PERIMETER ONE SHRUB PER 40 FT OF LOT PERIMETER SCREENING SHRUBS *70% OPACITY REQUIRED TO SCREEN PARKING FROM RIGHT OF WAY LEGEND EASEMENT CURB & GUTTER BUILDING RETAINING WALL SIGN PIPE BOLLARD STANDARD DUTY ASPHALT PAVING CONCRETE PAVING PROPERTY LIMIT EXISTINGPROPOSED HASTINGS LANDSCAPE CODE PLANT SCHEDULE WETLAND LIMITS TREELINE PROPOSED 46 103 166 121 CONCRETE SIDEWALK S S SANITARY SEWER LANDSCAPE EDING STORM SEWER WATERMAIN FORCEMAIN (SAN.) YARDDRAIN TREE PROTECTION FENCE LIMITS OF DISTURBANCE TREE TO BE REMOVED D S LS RIPRAP REQUIRED 46 103 129 * 1.One tree per 4,000 square feet of paved surface is required of which 75% must be deciduous, overstory trees.Trees shall be planted in medians or directly adjacent to the parking lot perimeter. 2.One tree per 50 feet of lot perimeter is required. Trees shall be planted every 50 feet along public and private street frontages between the front lot line and back of curb. Remaining trees can be placed somewhere else on the site. 3.At least one shrub per 40 feet of lot perimeter must be planted. 4.An opaque landscaping feature a minimum of 30 inches in height is required between any parking lot or driveway and the adjacent street. --10-foot wide landscaped strip which must screen at least 70% of the length of the lot frontage with an opaque barrier 30 inches high at initial planting --Landscaped berms at least 3 feet in height measured from the top of street curb adjacent to the berm at a slope not greater than 3:1. TREES CODE BOTANICAL / COMMON NAME CONT CAL SIZE QTY SG Acer freemanii `Sienna Glen` / Sienna Glen Maple B & B 2.5"Cal 14 RB Betula nigra `Cully` TM / Heritage Birch B & B 2.5"Cal 4 WS Betula papyrifera `Whitespire` / Whitespire Birch B & B 2.5"Cal 10 IH Gleditsia triacanthos `Imperial` / Imperial Honeylocust B & B 2.5"Cal 14 RP Quercus robur x warei`Long` / Regal Prince Oak B & B 2.5"Cal 18 BL Tilia americana `Boulevard` / Boulevard Linden B & B 2.5"Cal 21 CONIFERS CODE BOTANICAL / COMMON NAME CONT CAL SIZE QTY BF Abies balsamea / Balsam Fir B & B 6`24 BS Picea glauca densata / Black Hills Spruce B & B 6`24 WP Pinus strobus / White Pine B & B 6`14 TO Thuja occidentalis / American Arborvitae B & B 7`6 SHRUBS CODE BOTANICAL / COMMON NAME CONT LH Hydrangea paniculata `Jane` / Little Lime Hydrangea 5 gal 50 TN Physocarpus opulifolius `SMPOTW` / Tiny Wine Ninebark 5 gal 38 GS Spiraea japonica `Goldflame` / Spirea 5 gal 36 LB Syringa x `Bloomerang` / Lilac 5 gal 83 HA Thuja occidentalis `Holmstrup` / Holmstrup Cedar 10 gal 80 PERENNIALS CODE BOTANICAL / COMMON NAME CONT SBA Allium x `Summer Beauty` / Summer Beauty Allium 1 gal 51 BIG Geranium x cantabrigiense `Biokovo` / Biokovo Cranesbill 1 gal 74 RSH Hosta x `Regal Splendor` / Plantain Lily 1 gal 89 PLANT SCHEDULE